Gas Meter S-type
Model NO. SA25MT-ULS SA25MT-XLS
Gas Meter Authorization Expiry Period 10 years
Max. Flow Rate 2.5 m3/h
Connector Specifications Piping 15 A or 20 A (Depending on connector)
Spacing Between
In & Out
90 mm 130 mm
Connection Diameter M36 × 2
Inflow Direction left
Micro computer Controller Security Functions Shutdown Excess/Increased flow, Preset usage time (a la carte response), Low battery voltage, Voltage alarm detection, Security confirmation leakage after restoration, Test , Seismic sensor, Pressure drop, Gas detector, Remote sensor 1
Alert Leakage detection by micro flow, Low battery voltage, Shutdown fialure, Leakage detection by micro pressure drop, Abnormal setting pressure, Abnormal lock-up pressure
Display
Function
LCD Shutdown, Alert, Shutdown area, Auto setting, etc.
LED Shutdown, Leakage detection by micro flow, Shutdown failure
Communications functions Security Functions Shutdown, Alert, Usage time shutoff notice, Call out to shutoff valve restoration, etc., Detailed shutdown data, Leak detection by micro flow timer, Test call, etc.
Type of Signal
Communications (N and H lines): KHK common e-script, Gas detector, Remote sensor 1 and 2, Remote opening and closing: Non-voltage contacts
Power Supply Lithium Battery
Working Temperature – 30 ℃ – 60 ℃
Standard Painting Color Light gray equivalent to Muncell 5Y7.5/1
Weight 2.0kg 2.0kg
Price
Drawings CAD Performance curve Maunal Product picture
SA25MT-ULS
SA25MT-XLS
E4・EB-Type Gas-meter
E4-Type EB-Type

Model No. EY4MT-ZL EY4MT-YL EBY6 EBY10 EBY16
Gas Meter Authorization Expiry Period 10 years
Max. Flow Rate 4.0 m3/h 6.0 m3/h 10 m3/h 16 m3/h
Connector Specifications Piping 20 A (Depending on connector)
Spacing Between
In & Out
90 mm 130 mm 220 mm
Connection Diameter M36 × 2 M56 × 2 M64 × 2
Inflow Direction left
Micro computer Controller Security Functions Shutdown Excess / Increased flow, Preset usage time, Security confirmation leakage after restoration Excess / Increased flow, Security confirmation leakage after restoration
Shutdown / Other Seismic sensor, Pressure drop,Gas detector, External Equipment Coordinate, Test, Low battery voltage, Center, In emergency, Prepay *1, Expiry date
Alert Leakage detection by micro flow, Low battery voltage,
Shutdown failure, Leakage detection by micro pressure drop, Abnormal setting pressure, Abnormal lock-up pressure, Prepay *1, Expiry date, Reverse flow, Plug pulled out
Type of Signal Display Function 1.Pilot Flame Registering     
2.Operating state of Auto setting
3.Shutdown area of Increased flow 
4.Usage time shutdown value Status
5.Shutdown        
6.Alert
1.Pilot Flame Registering
2.Operating state of Auto setting
3.Shutdown area of Increased flow
4.Shutdown  
5.Alert
Communications System Half-duplex communication System
Pulse signal 1 L・10 L・100 L/Pulse Switching System
Power Supply Lithium Battery(DC3V)
Standard Painting Color Light Gray
Dimensions H 140 × W 174 × D 107.5(mm) H 147 × W 200×
D 118.5(mm)
H 231 × W 299 × D 142(mm)
Weight Approx. 2 kg Approx. 4.4 kg
Price

※ 1 EBY10,EBY16 are not included.

Microcomputer meter: SB‐type
SB-Type

Model No. SBA4-1 SBA6-1 SBA10-1 SBAL10-1 SBA16-1
Gas Meter Authorization Expiry Period 10 years 7 years
Max. Flow Rate 4 m3/h 6 m3/h 10 m3/h 16 m3/h
Connector Specifications Piping 20 A 32 A 40 A
Spacing Between-
In & Out
130 mm 220 mm
Connection Diameter M34 × 1.5
W 36.3 11.5 cam/inch
M34 × 1.5
W36.3
11.5 cam/inch
M56 × 2 M64 × 2
Micro Computer Controller Security Functions Shutdown Excess/Increased flow, Security confirmation leakage after restoration, Voltage alarm detection, Test , Gas detector, Seismic sensor, Pressure drop, Remote sensor 1 , Detector disconnected detection, Usage time shutoff (Available SBA4 only), Low battery voltage
Alert Leakage detection by micro flow, Low battery voltage, Shutdown failure, Leak detection by micro pressure, Abnormal setting pressure, Abnormal lock-up pressure
Display
Function
LCD Shutdown, Alert, Shutdown area, Auto setting, etc.
LED
(single aspect)
Shutdown, Leakage detection by micro flow, Shutdown failure
Communications functions
(Built in as standard)
Security Shutdown, Alert, Call out to shutoff valve restoration, etc., Detailed shutdown data, Leak detection by micro flow timer, Test call, etc.
Type of Signal Communications: KHK common e-script Gas detector, Remote sensor 1 and 2, Remote opening and closing: Non-voltage contacts
Power Supply Lithium battery
Atmospheric Temperature Range – 30 ℃ – 60 ℃
Standard Painting Color White (JPMA R4‐383)
Weight 5.1 kg 6.7 kg 11.6 kg
Price
Drawing CAD Performance curve Manual product Photos
SBA4-1
SBA6-1
SBA10-1
SBAL10-1
SBAL16-1
Gas-meter with a built-in shutoff valve:NV‐type
NV‐type
Model No. NV25 NV40
Effective Use Period 7 years 7 years
Max. Flow Rate 25.0 m3/h 40.0 m3/h
Volume of Measurement 9.0 L/rev 20.0 L/rev
Max. Capacity Pressure 10.0 kPa 10.0 kPa
Normal Working Pressure 3.5 kPa 3.5 kPa
Max. Indicating Quantity 99,999 m3 999,999 m3
Min. Indicating Quantity 2.0 L 20.0 L
Spacing Between In & Out 220 mm 320 mm
Connection Diameter
(see note)
T M72 × 3 M72 × 3
O W76.2 11 cam/inch W76.2 11 cam/inch
N M64 × 2 M72 × 2
Piping
(see note)
T 50 A 50 A
O
N 40 A 50 A
Inflow Direction left left
Weight 24 kg 41 kg
Standard Painting Color Off-white Off-white
Dimensions H 490 mm 615 mm
W 418 mm 513 mm
D 382 mm 442 mm
h 452 mm 574 mm
A 220 mm 320 mm
B 184 mm 212 mm
Price

Note: Three types (Generally separated by region). T: Tokyo dies; O: Osaka dies; N: Nagoya dies

nv_size

Drawing CAD Performance curve Manual product Photos
NV25
NV40

※各ファイルは右クリック「名前をつけて保存」からダウンロードして下さい