Bypass Unit Single-Stage Form

Single-Stage Form


KBU-50B
(To place the Automatic changeover on the right side is available)
KBU-20A KBU-30A KBU-50B KBU-70B KBU-70G
Capacity (Q) 20kg/h 30kg/h 50kg/h 70kg/h 70kg/h
(See Note1)
Inlet Pressure (P1) 0.1 – 1.56MPa
Outlet Pressure (P2) 2.8 ± 0.5kPa
Width x Height
(See Note 2)
1,159 × 1,038mm 1,754 × 757mm 1,937 × 1,086mm
Inlet Connection JIS 20K 15A Flanged JIS 20K 20A Flanged
Outlet Connection Rc1 · ½
(Female screwed)
Rc2
(Female screwed)
Pressure of Activating Safety Valve 7 ± 1.4kPa
Price
KBU-100 KBU-100G KBU-200 KBU-200G
Capacity (Q) 100kg/h 100kg/h
(See Note1)
200kg/h 200kg/h
(See Note1)
Inlet Pressure (P1) 0.1 – 1.56MPa
Outlet Pressure (P2) 2.8 ± 0.5kPa
Width x Height
(See Note 2)
2,100 × 767mm 2,100 × 937mm 2,330 × 944mm 2,330 × 1,144mm
Inlet Connection JIS 20K 25A Flanged
Outlet Connection Rc2
(Female screwed)
Rc4
(Female screwed)
Pressure of Activating Safety Valve 7 ± 1.4kPa
Price

Note 1: With earthquake-resistant shutoff device.
Note 2: The above width is for space between both sides flange.
The length does not include the thickness of the blind flange and the flange packing.
Height is the dimension from the center of the integrated header to the center of the drain pot.

Drawings CAD Performance curve Maunal Product picture
KBU-20A
KBU-30A
KBU-50B
KBU-70B
KBU-70G
KBU-100
KBU-100G
KBU-200
KBU-200G

※各ファイルは右クリック「名前をつけて保存」からダウンロードして下さい

Bypass Unit Single-Stage Form(Switching Type Leak Detection Device)
Single-Stage Form
Switching Type Leak Detection Device
KBU-20AHL KBU-30AHL KBU-50BHL
Capacity (Q) 20kg / h 30kg / h 50kg / h
Inlet Pressure (P1) 0.1 – 1.56MPa
Outlet Pressure (P2) 2.8 ± 0.5kPa
Width x Height
(See Note 1)
1,159 × 1,030mm 1,754 × 757mm
Inlet Connection JIS 20K 15A Flanged JIS 20K 20A Flanged
Outlet Connection Rc1 · ½
(Female screwed)
Pressure of Activating Safety Valve 7 ± 1.4kPa
Price

Note 1: The above width is for space between both sides flange.
The length does not include the thickness of the blind flange and the flange packing.
Height is the dimension from the center of the integrated header to the center of the drain pot.

Drawings CAD Performance curve Maunal Product picture
KBU-20AHL
KBU-30AHL
KBU-50BHL

※各ファイルは右クリック「名前をつけて保存」からダウンロードして下さい

Bypass Unit Low Pressure W Form

Low Pressure W Form

KWU-70 KWU-100 KWU-100G KWU-200 KWU-200G
Capacity (Q) 70kg/h 100kg/h 100kg/h
(See Note1)
200kg/h 200kg/h
(See Note1)
Inlet Pressure (P1) 0.1 – 1.56MPa
Outlet Pressure (P2) 2.8 ± 0.5kPa
Width x Height
(See Note 2)
1,483×1,329mm 1,680×1,200mm 1,920×939mm 2,055×1,195mm 2,055×1,230mm
Inlet Connection JIS 20K
20A Flanged
JIS 20K
25A Flanged
Outlet Connection Rc2
(Female screwed)
Rc4
(Female screwed)
Pressure of Activating Safety Valve 7 ± 1.4kPa
Price

Note)

Note 1: With earthquake-resistant shutoff device.
Note 2: The above width is for space between both sides flange.
The length does not include the thickness of the blind flange and the flange packing.
Height is the dimension from the center of the integrated header to the center of the drain pot.


Drawings CAD Performance curve Maunal Product picture
KWU-70
KWU-100
KWU-100G
KWU-200
KWU-200G