Gas Alarm All-in-one Type

KF-01/KF-01(S) KF-01(D)
KF-01 KF-01(S) KF-01(D)
Type All-in-one type
Principle of Detection Catalytic combustion type
Applicable Gas LPG
Density of Alarming 1/100 or more to 1/4 or less of L.E.L.
Method of Alarm Buzzer sound (auto reset method) and Red LED blinking
Indication of Power-ON Red LED lighting
Power Supply Rated AC100 V, Rated frequency 50/60 Hz
Power Consumption 0.8 W in watch, 0.9 W in alarm
Working Temperature -10℃ to 40℃ (Without dew condensation)
Special Functions Pause Alarm Functions Gas leak alarm: Buzzer sound only stops for approx. 1 min.
Malfunction alarm: Buzzer sound only stops for approx. 36 hours
Failure Alarm Functions Buzzer sound at an interval of 1 min. and Red LED rapid blinking
Expired Notification Function Red LED slow blinking after the expiration of period
Method of Mounting Wall mounting with mounting plate Plug type outlet
Power Cable Length 2.5m 0.35m None
Dimensions H78×W62×D31mm H62×W78×D35mm
Weight Approx. 195 g Approx. 125 g Approx. 115 g
Accessories Mounting plate x 1, Cable stopper x 1, Screws x 3 (Mounting platex 2, Stopper x 1) Without mounting plate, Cable stopper and screws
Gas for Inspection x 1, User manual (with warranty) x 1, “If buzzer sounds…” Sticker x 1
Price
KX-01
KX-01
Type All-in-one type
Principle of Detection Semiconductor Type
Applicable Gas LPG
Density of Alarming 1/100 or more to 1/4 or less of L.E.L.
Method of Alarm Sweep (1 kHz to 4 kHz) and Red lamp Immediate Blinking (Auto reset method)
Indication of Power-ON Red LED lighting
Power Supply Rated AC100 V ± 10%, Rated frequency 50/60 Hz
Power Consumption 0.9 W in watch, 0.9 W in alarm
Working Temperature -10℃ to 40℃ (Without dew condensation)
Special Functions Pause Alarm Functions Gas leak alarm: Buzzer sound only stops for approx. 1 min.
Malfunction alarm: Buzzer sound only stops for approx. 36 hours.
Failure Alarm Functions Electronic sound at an interval of 50 sec. and Red lamp rapid blinking
Expired Notification Function Red lamp slow blinking after the expiration of period
Method of Mounting Wall mounting with mounting plate
Power Cable Length 2.5m
Dimensions H62×W80×D32mm
Weight Approx. 210 g
Accessories Mounting fittings, Cable stopper, Screws, Double-faced tape,
Inspection gas sampler, User manual (with warranty) x 1, “If buzzer sounds..” Sticker x 1
Price

図面 CAD 性能曲線 取扱説明書 製品写真
KF-01
KF-01(S)
KF-01(D)
KX-01

S-Type Microcomputer Meter Linked
KF-13F
Model No. KF-13F Special Functions Pause Alarm Functions When pressing the pushbutton Gas leak alarm Buzzer sound only stops for approx. 1 min.
Type All-in-one type Sensor malfunction is displayed Buzzer sound only stops for approx. 36 hours.
Principle of Detection Semiconductor type Speaker Inspection Functions Normally Speaker inspection. Buzzer sound can be checked.
Applicable Gas LPG Meter Shutoff
Inspection
Functions
Normally Shutoff inspection can be completed by Inspection gas in 10 sec.
Density of Alarming 1/100 or more to 1/4 or less of L.E.L. Expired
Notification
Function
Red lamp slow blinking after the expiration of period
Method of Alarm Buzzer sound (auto reset method) and Red LED blinking Other Malfunction diagnosis function, Initial alarm prevention function,
Alarm history function
Method of Mounting Wall mounting with mounting plate
Initial Stabilization 5 min.(Red lamp blinking during setup) Power Cable Length 2.5 m plug with backup outlet(Max. 1,490 W)
Indication of Power-ON Red LED lighting Dimensions H117 × W70 × D29 mm
Power Supply Rated AC100 V ± 10%,
Rated frequency 50/60 Hz
Weight Approx. 250 g
Accessories Mounting fittings x 1, Cable stoppers x1
Screws x 5, Inspection gas sampler x 1
User manual (with warranty) x 1
“If buzzer sounds..” Sticker x 1
Power Consumption 0.8 W in watch
0.9 W in alarm
Working Temperature -10℃ to 40℃ (Without dew condensation)
Price

Drawings CAD Performance curve Maunal Product picture
KF-13F

※各ファイルは右クリック「名前をつけて保存」からダウンロードして下さい

External Linked Type for Central Monitoring
KF-16F

Model No. KF-16F Special Functions Pause Alarm Functions When pressing
the pushbutton
Gas leak alarm Buzzer sound only stops for approx. 1 min.
Type All-in-one type Sensor malfunction is displayed Buzzer sound only stops for approx. 36 hours.
Principle of Detection Catalytic combustion type Speaker Inspection Functions Normally Speaker inspection. Buzzer sound can be checked.
Applicable Gas LPG Meter Shutoff Inspection Functions Normally Shutoff inspection can be completed by Inspection gas in 10 sec.
(Obsolete types: 60 sec.)
Density of Alarming 1/100 or more to
1/4 or
less of L.E.L.
Expired Notification Function Red lamp slow blinking after the expiration of period
Method of Alarm Buzzer sound
(auto reset method)
and Red LED blinking
Other Malfunction diagnosis function
Initial alarm prevention function,Alarm history function
Method of Mounting Wall mounting with mounting plate
Power Cable Length 2.5 m plug with backup outlet(Max. 1,490 W)
Indication of Power-ON Red LED lighting Dimensions H117×W70×D29mm
Power Supply Rated AC100 V ± 10%,
Rated frequency
50/60 Hz
Weight Approx. 220 g
Accessories Mounting fittings x 1, Cable stoppers x1
Screws x 2, Inspection gas sampler x 1
User manual (with warranty) x 1、 “If buzzer sounds..” Sticker x 1
Power Consumption 0.8 W in watch
0.9 W in alarm
Working Temperature Range -10℃ to 40℃ (Without dew condensation)
Price

Drawings CAD Performance curve Maunal Product picture
KF-16F

KP-35D
Type KP-35D Output Specifications Type DC 0-6-12 V
Type All-in-one type(cordless) Working Load 1.2kΩ – 50kΩ
Principle of Detection Catalytic combustion type Initial Stabilization 0 sec.
Applicable Gas LPG Special Functions Initial alarm prevention function (40 sec.) (Red LED lighting) Sensor negative drift alarm function (buzzer)
Density of Alarming 1/100 or more to 1/4
or less of L.E.L.
Method of Alarm Buzzer sound(auto reset method)and Red LED blinking Method of Mounting Wall mounting with dedicated mounting plate (KP-35B)
Dimensions H110 × W110 × D42 mm<
Indication of Power-ON Green LED lighting Weight Approx. 180 g
Power Supply DC24 V
(Allowance voltage:
DC17 V to 35 V)
Accessories User manual (with warranty) x 1
Gas for inspection x 1
“If buzzer sounds.” Sticker x 1
Power Consumption 0.8 W in watch
1 W in alarm
Working Temperature and Humidity -10℃ to 40℃,85% RH or less
Price

Drawings CAD Performance curve Maunal Product picture
KP-35D

※各ファイルは右クリック「名前をつけて保存」からダウンロードして下さい

External Linked Type for Shutoff Valve
KP-31A

Model No. KP-31A Delay to Shutoff 45 ± 15 sec.
Type All-in-one type Valve Cable Lengthh Line resistance (both ways) 2Ω or less
Principle of Detection Catalytic combustion type Working Temperature -10 ℃ – 40 ℃
(Without dew condensation)
Applicable Gas LPG Power Supply AC100 V ± 10% 50 / 60 Hz
Density of Alarming 1/100 or more to 1/4 or less of L.E.L. Power Consumption 1.1W in watch,
1.3 W in alarm
Mounting Method Wall mounting with mounting plate
Method of Alarm Buzzer sound (auto reset method) and Red LED blinking Power Cable Length Approx. 3 m
Indication of Power-ON Green LED lighting External Dimensions H 100 × W 62 × D 42.5 mm
Compatible Shutoff Valve Low-pressure shutoff valve,
V-series
Weight Approx. 280 g
Multiple Linked Up to 5 pcs. of KP-31 can be connected for 1 pce. of shutoff valve. Shutoff valves for a KP-31 is not available. Accessories Mounting plate x 1, Screws x 5,
Gas for inspection x 1, Cable holder x 3,
User manual (with warranty) x 1, “If buzzer sounds..” Sticker x 1, Crimp contacts x 2
Valve Shutoff Signal One-shot electric discharge condenser. Discharge from 470μF ± 20% condenser (charging voltage 13.5 + 1.5/ -0.5V)
Price

Drawings CAD Performance curve Maunal Product picture
KP-31

※各ファイルは右クリック「名前をつけて保存」からダウンロードして下さい

Separate Type (Detector: Damp & Drip-Proof)
KX-55

Model No. KX-55 Initial Alarm Prevention Time Approx. 40 s
(Red LED blinking)
Type Separate type
(Detector: Damp & Drip-proof)
Mounting Method
Alarm Part
Wall mounting with mounting plate and swichbox
Mounting Method Heatable Semiconductor Detector Part Wall mounting with mounting fittings
Applicable Gas LPG External
Dimensions
Alarm Part H 125 × W 92 × D 45 mm
Density of Alarming 1/100 or more to 1/4 or less of L.E.L. Detector Part H 65× W 55 × D 36 mm
Method of Alarm uzzer sound (auto reset method) and Red LED blinking Power Cable Length Approx. 2.5 m
Detector Cable Length Approx. 5 m(0.3 m㎡ 3-core cabtyre cable)
Indication of Power-ON Red LED lighting
Detector Extension
0.3 mm 3-core cabtyre cable From detector to alarm: Within 20 m
Power Consumption AC100 V ± 10%
50/60 Hz
Weight Approx. 270 g(including detector cable)
Power Consumption 1.0Win watch,1.6W in alarm Special Functions Initial alarm prevention function (40 sec.) (Red LED blinking) Sensor negative drift alarm function: Buzzer
Working Temperature -10℃ – 40℃
Working Humidity Alarm Part 85% RH or less
Detector Part 95% RH or less Accessories Alarm Part Mounting plate x 1、Cable holder x 3
Anchor pulg × 2、Screws x 3、
Countersunk screw × 2
Output Specifications Type Voltage Output DC0V-6V-12V
Contact output (Normal open) Phototransistor Open Collector outputs Detector Part Mounting plate x 1、Cable holder x 8,
Anchor pulg×2、Screws x 2、
Countersunk screw × 2
Two steps of voltage DC0V-6V-12V
Delay to Shutoff 30 sec. Others User manual (with warranty) x 1,
Operation manual、
「”If buzzer sounds…” Sticker x 1,
Gas for inspection x 1
Connection Method Connected to Screwless Terminal Block(2P)
Price

Drawings CAD Performance curve Maunal Product picture
KX-55